NEW II

Environmentally Preferred Parts Cleaner

Meets MIL-PRF-680A, Type II


Printer-formatted versions (Adobe Acrobat PDF):
Product Data Sheet Material Safety Data Sheet

Description

NEW II Environmentally Preferred Parts Cleaner is an exceptional solvent degreaser formulated without chlorinated solvents or other hazardous ingredients. The base for NEW II is a unique high-grade hydrocarbon that provides its strength, has no odor and has a high flash point, allowing safe use on all types of mechanical apparatus. With its high flash point, NEW II provides an unprecedented degree of user safety.

NEW II Environmentally Preferred Parts Cleaner is strong enough to remove grease, fuel oil, carbon and organic resins yet safe on most plastic and rubber surfaces. Unlike other solvents, NEW II can be used without extensive protective equipment. Common sense chemical precautions required. (See MSDS).

Benefits

  • Odorless
  • Contains no water
  • Fully evaporative, leaves no residue
  • No hazardous ingredients as defined by the EPA
  • Meets all requirements to MIL-PRF-680A, Type II
  • Conforms to numerous corrosion test requirements
  • High flashpoint

Applications

Use undiluted. NEW II works very well in a drum mounted parts washer or any immersion tank. (Not for use in high pressure enclosed cabinets.) You may also spray or wipe NEW II on a surface to be cleaned. Oil, dirt and carbon will flow off surface. If additional cleaning is required, re-apply and agitate with rag or brush. To speed evaporation, use compressed air or wipe with a dry rag.

After cleaning, force out remaining solvent with compressed air and dry with filtered compressed air or heat gun set at 200°F. Since NEW II does not dry as rapidly as some hazardous solvents, apply a light spray first, allow 5-10 minutes to work, then follow with a light spray as a rinse, which will push out the dissolved soils.

Key Physical Characteristics

Physical Property

Test

Typical Value

Boiling Point, (IPB - FBP)

ASTM D-86

370° F (188° C)

Color, Saybolt

ASTM D-156

+30

Doctor Test

ASTM D-235

Conforms

Dry Point

ASTM D-86

403° F (206° C)

Flash Point (TCC)

ASTM D-56

145° F (63° C)

Kauri-Butanol No.

ASTM D-1133

27

Non-Volatile Residue

ASTM D-1353

< 5 mg/100 ml

Physical Form

Appearance

Clear Liquid

Pounds per Gal, (60° F)

Calculated

6.59

Soil Cleaning Test

Army Method

Conforms

Specific Gravity, (60° F)

ASTM D-1298

0.790

Vapor Pressure

ASTM D-2879

0.13 @ 20° C

Total Benzene Content

EPA 8240/8260B

<1250 ug/L

Dichlorobenzene Content

EPA 8240/8260B

<1250 ug/L

Phenol Content

EPA 420.1

<1.0 mg/L

Tetrachloroethene Content

EPA 8240/8260B

<1250 ug/L

Trichloroethene Content

EPA 8240/8260B

<1250 ug/L

VOC

 

767 gm/l

(N/A = Not Applicable N/E = Not Established)

Safety and Handling Precautions

Always use with adequate ventilation. Rubber gloves are recommended. Treat as combustible liquid. Place rags in a metal sealable container after use to avoid possible spontaneous combustion. Keep container closed. Avoid excessive contact with fumes or liquid. Please read MSDS prior to use.

Packaging

Product Name

Part No.

Packaging

National Stock No.

NEW II

1156-55

55 Gal. Drum

6850-01-474-2316

NEW II

1156-5

5 Gal. Pail

6850-01-474-2317

NEW II

1156-15

15 Gal. Drum

6850-01-378-0698